Diamond Logo
Contact Us
Abbott Architect ci8200 Chemistry Analyzer
Abbott Architect ci8200 Chemistry AnalyzerAbbott Architect ci8200 Chemistry AnalyzerAbbott Architect ci8200 Chemistry AnalyzerAbbott Architect ci8200 Chemistry AnalyzerAbbott Architect ci8200 Chemistry AnalyzerAbbott Architect ci8200 Chemistry Analyzer

Abbott Architect ci8200 Chemistry Analyzer

Item# 0-AB-ARCHCI8200-ER

The Abbott Architect ci8200 Chemistry Analyzer, provided by Abbott Diagnostics

Equipment SupportService OptionsService OptionsConsumablesConsumablesQuality ControlsQuality ControlsService PartsService Parts

Package Size: EA




Refurbished Abbott Architect ci8200 Chemistry and Immunoassay Analyzer Refurbished Abbott Architect ci8200 rebuilt Down-To-Frame® to meet its original specification. Spend up to 70% less than new, with $0-down financing. The Abbott Architect ci8200 runs photometric, turbidimetric and ICT electrolyte chemistry alongside chemiluminescent immunoassays at up to 1,400 tests an hour, with 365 samples and up to 146 refrigerated reagent positions onboard. One System Control Center runs both analyzers. Refurbished by Diamond, it costs up to 70% less than a new system. Pay up to 70% less than you would for a new Architect ci8200. Run up to 1,200 chemistry tests an hour and up to 200 immunoassay tests an hour simultaneously. Load 365 samples through the Robotic Sample Handler and sample carousel, with 35 priority positions for STAT work. Pair the c8000 or i2000SR you already own with a refurbished partner to complete your ci8200. Finance up to $2 million with $0 down, and trade in the analyzers you're consolidating. Get both analyzers rebuilt Down-To-Frame® by an FDA-registered, ISO 13485:2016 certified refurbisher, then installed, verified and serviced by our own engineers. REQUEST A QUOTE Refurbished Abbott Architect ci8200 Analyzer installed in a laboratory by a Diamond field engineer How the Abbott Architect ci8200 runs chemistry and immunoassay together The ci8200 joins an Architect c8000 and an Architect i2000SR under one System Control Center, so your techs run both from one screen. Samples load through the Robotic Sample Handler or the sample carousel. Abbott uses identical technology, reagents and assay protocols across the Architect family, so results stay equivalent from one Architect system to the next. The c8000 chemistry side Run up to 1,200 photometric, turbidimetric and ICT electrolyte tests an hour from up to 121 refrigerated reagent positions. Measure sodium, potassium and chloride on the ICT module, which Abbott rates at 60,000 determinations. Extend the linear range of enzyme assays with FlexRate, and let the analyzer dilute out-of-range samples automatically. Measure hemolysis, icterus and lipemia indices on chemistry samples. Run alternative reagents on certain chemistry tests where your methods allow. The i2000SR immunoassay side Run up to 200 chemiluminescent microparticle immunoassay (CMIA) tests an hour with Abbott's CHEMIFLEX detection. Keep 25 refrigerated reagent positions loaded with liquid, ready-to-use reagents that stay stable onboard for 14 to 30 days. Calibrate with each new reagent lot, or when controls fall out of range. Run thyroid, fertility, cardiac and infectious disease assays from Abbott's Architect immunoassay menu on serum, plasma, whole blood and urine. Across the whole system Load 365 samples, with 35 priority positions held for STAT work. Use primary tubes 72 to 102 mm tall and 9.6 to 16.1 mm wide, or sample cups with a 50 µL dead volume. Catch clots and bubbles at aspiration on both analyzers. Send results to your LIS over a bidirectional RS-232 interface with host query, and keep 50,000 results onboard. Ask for the list of chemistry and immunoassay tests run on the ci8200 we have in stock, and check it against your menu. REQUEST ASSAYS Architect ci8200 throughput compared with the ci4100 and Alinity ci The ci8200 runs 500 more tests per hour than the Architect ci4100 and 150 fewer than the Alinity ci. It also takes the most floor space of the three, about 43.2 sq ft against 27.5 for the ci4100 and 25.1 for the Alinity ci. Choose the ci8200 when you need up to 1,200 chemistry and 200 immunoassay tests an hour, a 365-sample load and room for a fairly wide system (127 inches wide). Choose the ci4100 when 800 chemistry and 100 immunoassay tests an hour cover your volume and your floor space is tighter. Choose the Alinity ci when you want Abbott's current platform at up to 1,550 tests an hour on about 25 sq ft, with the option to add modules later. The chemistry rating counts each sodium, potassium and chloride result from the ICT module as a separate test, so your real hourly output depends on how much of your menu is electrolytes. SpecArchitect ci8200Architect ci4100Alinity ci Analyzers joinedc8000 and i2000SRc4000 and i1000SRAlinity c and Alinity i Maximum throughputUp to 1,400 tests/hour (1,200 chemistry, 200 immunoassay)Up to 900 tests/hour (800 chemistry, 100 immunoassay)Up to 1,550 tests/hour (1,350 chemistry, 200 immunoassay) Sample capacity365 (35 priority positions)180 (35 priority positions)300 Refrigerated reagent positionsUp to 146, plus ICTUp to 115, plus ICT117, plus ICT H x W x D48 x 127 x 49 in (121.9 x 322.6 x 124.5 cm)49 x 111 x 36 in (125.1 x 281.2 x 90.7 cm)53 x 78 x 46 in (134 x 199 x 117 cm) Footprint43.2 sq ft (4.02 m²)27.5 sq ft (2.55 m²)25.1 sq ft (2.33 m²) Weight2,447 lb (1,109.9 kg)1,677 lb (760.7 kg)2,557 lb (1,160 kg) Buy a complete ci8200 or build it around the analyzer you own Complete ci8200. We supply both analyzers and the System Control Center, rebuilt and installed together. Your c8000 plus a refurbished i2000SR. Add immunoassay to the chemistry analyzer your staff already run. Your i2000SR plus a refurbished c8000. Bring chemistry and electrolytes onto the immunoassay analyzer you own. One side only. If you need just chemistry or just immunoassay, we sell each module their own. A smaller option. If a ci8200 is more system than your volume needs, the ci4100 takes the same reagent cartridges and sample carriers and runs up to 900 tests an hour. ConfigurationUp to (tests/hour)Sample capacityRefrigerated reagent positionsH x W x DWeight Architect ci82001,400365146, plus ICT48 x 127 x 49 in (121.9 x 322.6 x 124.5 cm)2,447 lb (1,109.9 kg) Architect c8000 alone1,200215121, plus ICT48 x 79 x 49 in (121.9 x 200.6 x 124.5 cm)1,425 lb (646.4 kg) Architect i2000SR alone2001352548 x 61 x 49 in (121.9 x 154.9 x 124.5 cm)1,081 lb (490.3 kg) Abbott Architect ci8200 Analyzer configurations Tell us which Architect analyzers you run now and your daily chemistry and immunoassay volumes, and we'll recommend the setup. CHECK AVAILABILITY Plan floor space, power and water for your Architect ci8200 Run both analyzers on AC 180 to 264 V, 47 to 63 Hz. The c8000 needs a 20 A circuit. Plumb deionized water for chemistry, about 25 L (6.6 gal) an hour in normal operation. The immunoassay uses purified water to dilute its buffer concentrate. Size your HVAC for about 7,680 BTU an hour from the two analyzers in running mode (3,400 from the c8000 and 4,280 from the immunoassay), plus up to 389 BTU an hour from the System Control Center. Connect to your LIS over a bidirectional RS-232 serial interface with host query. Requirementc8000 chemistry sidei2000SR immunoassay side PowerAC 180 to 264 V, 47 to 63 Hz, 20 AAC 180 to 264 V, 47 to 63 Hz WaterDeionized, 25 L/hr (6.6 gal/hr) in normal operationPurified water to dilute buffer concentrate Heat output, running mode3,400 BTU/hr4,280 BTU/hr Host interfaceBidirectional RS-232 serial, host query optionBidirectional RS-232 serial, host query option Send us your room layout and utilities, and we'll check them against the ci8200 before you commit. Which labs buy a refurbished Abbott Architect ci8200? The ci8200 fits labs that run high chemistry volume alongside a full immunoassay menu and want both on one Architect system. Hospital core labs on Architect. Consolidate chemistry, electrolytes and immunoassay on one system, with 35 priority positions for ED and inpatient STAT samples. Labs outgrowing a ci4100. Gain 400 chemistry and 100 immunoassay tests an hour over the ci4100 without changing reagent cartridges or sample carriers. Labs replacing an older ci8200, or standalone chemistry and immunoassay. Swap in a rebuilt system and keep the methods and workflows your techs know. Labs running cardiac markers for the ED. A five-year review of QC data found stable high-sensitivity troponin I performance on Architect i2000SR analyzers. Labs shopping for a used ci8200. Compare any used system with one rebuilt to the frame, installed by our engineers and eligible for our field service plans. CONTACT US FOR INFO Abbott Architect ci8200 price: new, used or refurbished Abbott quotes new ci8200 systems by contract, often as part of a reagent agreement that builds the instrument cost into each test you run. Diamond prices every refurbished ci8200 individually. Whatever the configuration, you pay up to 70% less than new and the system is yours. Two analyzers means two histories to check. Before you weigh a used ci8200's asking price against a refurbished one, add what it will take to get both analyzers reporting patient results. What to ask about a used ci8200 What year was teach module manufactured? Were both analyzers decontaminated, and is there documentation? Which wear parts were replaced on each analyzer, and when? Do both analyzers pass calibration and multi-level QC now, and can you review the data? What software version is the system running? How many determinations remain on the chemistry analyzer’s ICT module? Who installs the system, programs your assays and verifies them? Who services it after go-live, and at what cost? Every refurbished ci8200 from Diamond is decontaminated, rebuilt with new wear parts on both analyzers, calibrated and QC-validated before it leaves our facility. Our engineers then install it and verify your assays in your lab. What sets the price of your ci8200 The year of manufacture. Whether you need the complete system or one analyzer to pair with yours. Installation, assay programming and verification for chemistry and immunoassay. Operator training. The service plan you choose. Freight and rigging for two analyzers. The trade-in value of the analyzers you're retiring. Why buy a refurbished ci8200 instead of new? A lower capital cost. Pay up to 70% less for a two-analyzer system. Only the half you're missing. Add to the Architect analyzer you already own. Ownership. Own the system outright rather than paying for it inside reagent pricing, and choose who services it. Results that match your Architect fleet. A refurbished ci8200 runs the same Abbott reagents and assay protocols as a new one, and we supply the reagents and consumables. Less waste. Rebuilding two analyzers keeps them in service and out of landfill, and uses less energy and raw material than manufacturing new ones. Get your ci8200 quote Send us the Architect analyzers you already own, your daily chemistry and immunoassay volumes and your go-live date, and we'll quote the configurations that fit. We'll show the figure as a monthly payment too, from $0 down with low introductory payments, so you can set it against a used system or a reagent agreement. REQUEST A QUOTE Why buy a refurbished Abbott Architect ci8200 from Diamond Diagnostics? Diamond rebuilds both analyzers, installs the joined system in your lab and keeps it running with its own field engineers. Diamond technician rebuilding an analyzer down to the frame beside finished refurbished analyzers An FDA-registered, ISO 13485:2016 certified refurbisher Diamond is registered with the FDA, and its US and EU facilities are certified to ISO 9001:2015 and ISO 13485:2016. ISO 13485 is the quality management standard for medical device manufacturers, and independent auditors check the work against both standards. Installed and verified as one system Our engineers install both analyzers, connect them to the System Control Center, program your chemistry and immunoassay menus and verify them before you report a patient result. After installation, your operators can take on-site training on the instrument, your menu, adding parameters, preventive maintenance and first-line troubleshooting, with an hour for questions at the end. Finance your ci8200 with $0 down Lease or finance up to $2 million. Apply for up to $400,000 on a credit application alone. Start at $0 down with low introductory payments. Get a fast credit decision and a broad choice of terms. Include freight and other purchase costs in the financing. Trade in the analyzers your ci8200 replaces Moving off separate chemistry and immunoassay analyzers, or an older Architect system? We'll buy what you're retiring and credit it toward the ci8200. Our team deinstalls and decontaminates the old analyzers, schedules the pickup and covers the freight, so you skip storage and disposal costs. REQUEST A QUOTE GET A TRADE-IN VALUE Field service from Diamond engineers Every ci8200 we sell qualifies for our field service plans. If you bought yours elsewhere, we qualify it first and then cover it the same way. Choose from four plans, from Platinum, with next-day response and 24/7 phone support, to Bronze, with first-available scheduling. Keep both analyzers on the manufacturer's preventive maintenance schedule at a fixed cost, booked around your lab's hours. Call or email clinical engineers who specialize in your model. Book assay programming, relocation, decommissioning and decontamination when you need them. Compare service plans REQUEST A SERVICE QUOTE Frequently asked questions about the Abbott Architect ci8200 Q: How many tests per hour does the Abbott Architect ci8200 run?A: Up to 1,400 tests an hour, with up to 1,200 on the c8000 chemistry side and up to 200 on the i2000SR immunoassay side. Q: How much does an Abbott Architect ci8200 cost?A: Abbott quotes new systems by contract, often inside a reagent agreement. A refurbished ci8200 from Diamond costs up to 70% less than new. Each system is priced individually, based on the year of manufacture of both analyzers, whether you need one analyzer or both, and the services you add. Q: Should I buy a used or a refurbished Architect ci8200?A: A used ci8200 carries two analyzers' histories, so ask the seller for each one's year of manufacture, decontamination records, replaced wear parts and current QC data. A refurbished ci8200 from Diamond is rebuilt to the frame on both sides, calibrated and QC-validated, then installed and verified by our engineers and eligible for our field service plans. Q: What's the difference between the Architect ci8200 and ci4100?A: The ci8200 joins a c8000 and an i2000SR and runs up to 1,400 tests an hour from 365 samples. The ci4100 joins a c4000 and an i1000SR and runs up to 900 tests an hour from 180 samples, in a system 111 inches wide against the ci8200's 127. Both take the same Architect reagent cartridges and sample carriers. Q: Should I buy an Architect ci8200 or an Alinity ci?A: The Alinity ci is Abbott's current platform, running up to 1,550 tests an hour on about 25 sq ft, with the option to add modules. The ci8200 runs up to 1,400 and keeps your lab on Architect, with the reagents, methods and training you already have. Q: I already own a c8000. Can you turn it into a ci8200?A: Yes. We pair a refurbished i2000SR with your c8000 and install them together as a ci8200. If you own an i2000SR, we add a refurbished c8000 instead. Q: What immunoassay tests run on the ci8200?A: The i2000SR runs thyroid, fertility, cardiac and infectious disease assays from Abbott's Architect immunoassay menu. Ask us for the list of tests run on the system in stock. Q: Can the ci8200 run non-Abbott reagents?A: On certain chemistry tests, yes, where your methods allow. Ask us which tests on your menu qualify. Q: What power and water does the ci8200 need?A: Both analyzers run on AC 180 to 264 V, 47 to 63 Hz, and the c8000 needs a 20 A circuit. The c8000 uses about 25 L (6.6 gal) of deionized water an hour, and the i2000SR uses purified water to dilute its buffer. Q: What financing is available for a refurbished ci8200?A: Lease or finance up to $2 million with $0 down and low introductory payments. Up to $400,000 needs only a credit application, and freight can go into the financed amount. Q: Will you take our current analyzers in trade?A: Yes. We buy the analyzers you're retiring, credit their value toward your ci8200, and handle deinstallation, decontamination, pickup and freight. Q: Do you install the ci8200 and train our staff?A: Yes. Our engineers install both analyzers, program and verify your chemistry and immunoassay tests, and offer on-site operator training after installation. Q: Can you service a ci8200 we bought somewhere else?A: Yes. Once we qualify it, it's eligible for the same field service plans as the systems we sell. Q: Can I get Architect ci8200 reagents from Diamond?A: Yes. Reagents and consumables for both the c8000 and the i2000SR are available through Diamond Diagnostics. REQUEST A QUOTE

Down-To-Frame Refurbishment Process

Factory Refurbished
FDA ISO

Upgrading or Adding Equipment to your lab?

Save up to 70% with refurbished equipment from Abbott, Alfa Wasserman, Beckman, Biomerieux, Biotechnia, Hitachi, Horiba ABX, IL, J&J, Radiometer, Randox, Roche, Siemens, Stago, Sysmex, Thermo and Tosoh.

Diamond is the only USA FDA registered, ISO Certified and Down-To-Frame® refurbisher of Chemistry, Immunology, Hematology, Caogulation and Blood Gas equipment. Inquire today for pricing and Details.

Every analyzer undergoes a systemized, rigorous and unique Down-To-Frame® Refurbishment process to rebuild each analyzer to its original specification and intended use.

Disassembly
Aesthetics
Refurbishment
Diagnostics
Validation
Final Packing
Disassembly & Decommission
  • System decommissioned from laboratory and decontaminated
  • Preliminary inspection of functionality
  • System disassembled Down-To-Frame®
Aesthetic Restoration
  • All outer covers, chassis and internal surfaces stripped, sand blasted and prepared for painting
  • All prepared surfaces primed and painted with 3 part compound, color matched automotive quality paint
  • All original logos and signage are replaced in original appearance
Refurbishment & Reassembly
  • All mechanical, pneumatic, electronic assemblies disassembled, cleaned, restored, verified and reassembled, replaced where needed
  • Disposable components replaced with new components
  • New components include: tubing, fittings, syringes, seals, check valves, probes, reagent lines, waste assemblies and similar items
  • System completely reassembled into its original condition in accordance to protocol and established specifications
Diagnostics & Troubleshooting
  • Assembly Functions & System errors assessed, troubleshooting and repair conducted
  • Full system diagnostic testing conducted
  • System successfully calibrated with certified calibrator materials to ensure proper functionality
Performance Validation
  • Rigorous Multi-Level Quality Control testing conducted on established parameters using certified control material
  • Specific parameter testing available upon request
  • System checked for power stability, software revisions and other upgrades
Final Packing
  • Required peripherals for operation refurbished or provided new as needed
  • System properly flushed, drained, protected and prepared for storage
  • System professionally crated with heat-treated and non-coniferous wood for international transit

Performance & Configuration
Assays

128 Total Assays Tested

************(***), *********(****), *********(******), ************(******), ***********(***), ******(******), ***********(****), **********(*****), ********(*****), ***********(******), *******(****), **************(***), ********(******), ************(*****), ******(******), ********(*****), *******(***), *************(****), ***************(******), ******(******), *******(****), ******(***), ***********(*****), ***********(****), *************(*****), ******(*****), **************(****), ************(****), *******(*****), **********(****), ********(******), *********(******), ***************(******), ******(****), *************(***), ***************(*****), *******(******), *******(***), ********(*****), ******(*****), **************(*****), ******(***), *********(***), *********(***), *********(***), ************(*****), ***********(***), *******(*****), ***********(****), ********(****), **********(******), ***************(****), **************(****), ***************(*****), ********(****), **************(*****), ***************(****), *******(***), *******(****), *******(****), ************(***), *******(******), **************(*****), *************(******), **********(*****), ********(****), ********(***), ********(****), **********(*****), ***********(***), **************(****), **********(******), **************(***), ******(*****), **********(*****), ********(*****), *******(***), ******(****), ***************(****), *************(*****), *************(*****), *************(****), ***************(***), ************(*****), **********(******), ***********(****), *************(***), *************(*****), ******(*****), ***********(***), ***************(******), *********(******), **********(****), *********(***), *********(*****), **********(*****), *******(***), ************(****), ******(***), ******(*****), ***************(****), ***************(*****), ***************(****), **************(******), ************(******), ***************(*****), **************(***), **************(***), ***************(*****), *******(******), **************(****), ************(***), ************(*****), **********(*****), ******(******), ********(******), ***********(******), *************(***), **************(******), *******(******), **************(*****), *********(*****), ***************(****), *************(****), ********(******), **********(***), ***************(****), **************(******)

Technical Specifications
Private Labeled by:Toshiba Medical (now Canon Medical Systems)
Private Label Source Model:TO-CI8200
Series:Architect
CLIA Complexity:Moderate
Sample Types:CSF, Plasma, Urine, Whole Blood, Serum
Number of Assays:128
Maximum Throughput:1400 tests/hour
Sample Size Min:1.5 μL
Direct Sample (STAT):Yes
Auto Sample Handling:Yes
Sample Input Type:
Sample Cup
Sample Tube
Reagent Type:Liquid
Reagent System:Partial Open
Reagent Capacity:Up to 146 refrigerated positions (121 chemistry, 25 immunoassay), plus ICT
On-Board Refrigeration:Yes
Configuration:Floor Model
Height:122 cm (48 in)
Width:201 cm (79 in)
Depth:126 cm (49 in)
Weight:646 kg (1422 lb)
  
Unit #2i2000
Height:122 cm (48 in)
Width:155 cm (61 in)
Depth:125 cm (49 in)
Weight:490 kg (1079 lb)
Water Requirement:Yes
Water OnBoard Supply:No
Water Consumption:25 L/hour, deionized (c8000); purified water for buffer dilution (i2000SR) (L/hour)
Power Supply:220V
Point Of Care:No

All units sold by Diamond Diagnostics or units qualified by Diamond Diagnostics are eligible for Field Service coverage. Service plans are the best way to maximize your instrument investment and avoid the high costs associated with instrument failure. Our plans are designed to support optimum instrument performance, ensure reproducible results and minimize down-time. Our service plans provide a timely response from our dedicated engineers who are certified on an ongoing basis to ensure top-notch results, even in the most complex laboratory environments.

. Service OptionsPlatinumGoldSilverBronzeLaborLaborPer DiemTravelTravelPer VisitService PartsService PartsIncident TrackingIncident TrackingResponse TimeResponse TimeNext DayNext Business Day2 Business Days*First AvailablePhone SupportPhone SupportMon-Sun 0-24Mon-Sun 0-24Remote SupportRemote SupportHoliday SupportHoliday SupportPreventive MaintenancePrev Maintenance*Peripheral SupportPeripheral SupportComplimentary LoanerCompl LoanerRelocationRelocationRecommissionRecommissionDecommisionDecommisionDecontaminationDecontaminationTrainingTrainingAssay ProgrammingAssay ProgrammingIQ/OQ ValidationIQ/OQ Validation

: Included

: Chargeable

: None

* Contact for more details

Preventive Maintenance
Preventive Maintenance

For the laboratory looking to manage manufacture recommended preventative maintenance (PM) schedules for instrumentation at a fixed cost. The PM Service Plan will increase the reliability and reduce the risk and costs of unplanned maintenance and equipment downtime. Our plans are scheduled and planned around your specific instrument and operational needs.


Depot Service, Type 1
Depot Repair Per Diem

For the laboratory looking to maximize the life of their instrumentation while effectively managing repair costs. The Depot Repair is a per diem plan designed for any size instrument needing major repair, complete rebuild or recycling.


Depot Service, Type 2
Annual Depot Repair

For the laboratory looking to maximize the life of their instrumentation while effectively managing repair costs. Annual Depot Repair is an annual based plan designed for small to mid-sized instruments needing maintenance or repairs and can be easily shipped by your local carrier to our Depot Service Facility in Holliston, MA.


Phone Support
Phone Support

For the laboratory employing qualified service professionals, the Virtual Plan may be a suitable choice to replace or supplement Field Services. The Virtual plan offers its customers support by email and telephone, within business hours with communication directly with Clinical Engineering staff specialized in the model of instrumentation that the laboratory is utilizing. The Virtual Plan is annual.


Click here to learn more.

Related Products

The names and logos of manufacturers, their instruments, and their products referred to herein may be protected by trademark or other law, and are used herein solely for purpose of reference. Products are available for international distribution only unless otherwise indicated. Diamond Diagnostics expressly disclaims any affiliation with products it does not manufacture, as well as sponsorship by other manufacturers. For current regulatory status on products within this website, please contact your sales representative. Prices and Information shown are for reference only and may change without notice. SmartLyte®, ProLyte®, CareLyte®, and Down-To-Frame® Refurbishing are Registered Trademarks of Diamond Diagnostics®. No mobile information will be shared with third parties/affiliates for marketing/promotional purposes. All the above categories exclude text messaging originator opt-in data and consent; this information will not be shared with any third parties.

©2016-2026 Diamond Diagnostics®. All Rights Reserved.